Recent posts

Get Empowered: Review Window and the Processing Method | Tip #55, Deriving Channels

By February 7, 2018
Empower tip-of-the-week

#55: Have you ever had a sample where each component had a different lambda max and it was difficult to pick one wavelength to use for quantitation? We show how to use Timed Wavelength when Deriving Channels in Empower Software.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #54, Deriving Channels

By January 31, 2018
Empower tip-of-the-week

#54: We discuss another option for Deriving Channels in Empower Software when working with photodiode array (PDA) data, called RatioPlot.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #53, Deriving Channels

By January 24, 2018
Empower tip-of-the-week

#53: In this tip, we will discuss another option for Deriving Channels when working with PDA data, called TotalPlot.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #52, Deriving Channels

By January 17, 2018
Empower tip-of-the-week

#52: We discuss the options for Deriving Channels when working with PDA data, focusing on MaxPlot: A 2D chromatogram that plots each time point at the maximum absorbance across the wavelength range.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #51, Deriving Channels

By January 10, 2018
Empower tip-of-the-week

Tip #51: How do I subtract a baseline at a particular wavelength from my PDA data? More info on Deriving Channels in Empower Software.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , , ,

Get Empowered: Empower Tips #50 – A Year in Review

By January 4, 2018

Get Empowered: Review Window and the Processing Method | Tip #49, Deriving Channels

By December 27, 2017
Empower tip-of-the-week

Tip #49: How to subtract a baseline from a 2D chromatogram by Deriving a Channel (part 3) in Empower Software.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #48, Deriving Channels

By December 20, 2017
Empower tip-of-the-week

Tip #48: Learn how to correct for the time offset between detectors that are connected in series by Deriving a Channel in Empower Software. (Part 2)

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #47, Deriving Channels

By December 13, 2017
Empower tip-of-the-week

Tip #47: Smoothing a channel of chromatographic data collected with a UV detector through Empower Software’s Deriving Channels feature.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , ,

Get Empowered: Review Window and the Processing Method | Tip #46

By December 6, 2017
Empower tip-of-the-week

Tip #46: Recently I’ve had several questions about how baselines are determined using Empower Software’s ApexTrack peak integration algorithm. Let’s take a look at how they work.

Categories: Empower Tip-of-the-Week, Technologies
Tags: , , , , , , ,